Combined load frame with 1590 tonnes capacity. Tubular test samples can be tested in tension, compression and bending combined with internal and external pressure.
- Internal pressure with liquid or gas (N2, CO2, …)
- External liquid pressure
- Testing temperature from cryogenic to 350°C.
- Leak integrity testing, buckling testing, structural integrity testing and limit state testing
- All auxiliary equipment (power tong, bucking unit, bake out, …) for sample preparation of OCTG threaded connections is available
Testing according to
- API RP 5C5 and ISO 13679 (e.g. CAL IV qualification testing of premium connections)
- ISO 12835